Symptoms

Domain status is "Registered", renewal operation is completed on the registrar side, but the renewal order is stuck in "Provisioning" status or failed by timeout.

Cause

Check the logs for the time renewal attempt was made, if you see any kind of exception for dns.syncDomainRegistrationInfo, e.g.:

[18-03-14 03:18:06.496 XMLRPC      RQ2167146 TH03855 TRC] REQUEST: dns.syncDomainRegistrationInfo : { 'domain_name' => 'example.com', 'registration_info' => '{
.............
[18-03-14 03:18:06.498 XMLRPC      RQ2167146 TH03855 ERR] ERROR (network_error) in calling dns.syncDomainRegistrationInfo: Connector: Connection refused

then the root cause of the issue is a bug with id #PBA-84238 ("Domain renewal order is stuck in Provisioning if calling OA method is failed").

Resolution

Complete the renewal order manually, using the domain conflict resolver ("Complete Operation Manually" button).