Symptoms
The task massUpdatePanelApps
first was in rescheduled status:
"Asynchronous execution of operation with ID: 085f051c-a668-4a5d-820a-abfea57bd411 has been rescheduled.
Additional information: Updating Plesk in VPS Panel applications..."
Then failed with the following error:
The remote server is temporarily down, details:
system exception, ID 'IDL:omg.org/CORBA/TRANSIENT:1.0'
OMG minor code (2), described as 'No usable profile in IOR.', completed = NO
Cause
OA services were restarted during the task run.
Resolution
Please resubmit the task.