Symptoms

After upgrade to Odin Automation 7.2 task Execute operation 'massUpdatePanelApps' fails with the error like:

stderr: cp: cannot stat '/usr/local/aps/059873c1-7d17-4f1e-bd25-edea1b5873e2/scripts/config/*': No such file or directory

Cause

Application instance upgrade might initially fail due to various reasons.

However, rollback scenario incorrectly covers the situation, leaving certificates in the temporary location.

As a result, on next task reruns, the application cannot establish a connection with the APS Controller.

This behaviour is acknowledged as CCU-17558.

Resolution

Contact your Technical Account Manager to trace the status of CCU-17558.

Contact Technical Support to fix affected application instances.

Internal content

Link on internal Article